Standards |
EN 60947-5-1; EN 1088; EN 60079-0, EN 60079-1, EN 60079-7, EN 60079-18; EN 61241-0, EN 61241-1; EN ISO 13849-1 |
Enclosure |
glass-fibre reinforced, shock-resistant thermoplastic, self-extinguishing UL 94-V0 |
Actuator |
stainless steel 1.4301 |
Switch insert |
Ex 95 |
Degree of protection |
IP 64 to IEC/EN 60529 |
Contact material |
silver |
Switching system |
slow action, positive break NC contact |
Switching elements |
2 NC and 2 NO contacts with positive break, galvanically separated contact bridges |
Connection |
M3 screw clamps |
B10d(10% Load) |
1 million |
TM |
max. 20 years |
Cable section |
max. 1.5 mm2 (incl. conductor ferrules) |
Cable entries |
2 x M20 x 1.5 for cable section 5 … 9 mm |
Uimp |
4 kV |
Ui |
250 V |
Ithe |
6 A |
Ie/Ue |
3 A/250 VAC; 0.25 A/230 VDC |
Utilisation category |
AC-15, DC-13 |
Max. fuse rating |
6 A gL/gG D-fuse |
Ie/Ue solenoid |
0.08 A / 24 VDC +10%/–15% |
Power consumption |
max. 47 W (0,25s) |
Ambient temperature |
–20 °C … +55 °C |
Mechanical life |
> 500.000 operations |
Ex marking |
II 2G Ex demb IIC T4 Gb, II 2D Ex tD A21 IP64 T100°C IECEx Ex demb IIC T4, Ex tD A21 IP64 T100°C |
Approvals |
BVS 10 ATEX E 053 X IECEx BVS 11.0030X |