Ex zone 1 and 21
Special version up to +90°C ambient temperature for dust Ex zone 21 available (HU)
Two Ex switch inserts in one enclosure
Spring-to-lock or power-to-lock principle
Problem-free opening of stressed doors by means of bell-crank system
High holding force 3.500 N
Ball catch
Wiring compartment
Special version only for dust Ex zone 22 available
N.B.: Please state required approvals for Russia, China, Brazil and North America with your order!
Standards |
EN 60947-5-1; EN 1088; EN 60079-0, EN 60079-1, EN 60079-7, EN 60079-18; EN ISO 13849-1 |
Enclosure |
aluminium die cast, enamelled |
Cover |
steel, enamelled |
Actuator/locking bolt |
metal zinc/aluminium |
Switch insert |
Ex 95 |
Degree of protection |
IP 67 to IEC/EN 60529; Ex AZM 415-TE, TEI, -FE: IP 64 to IEC/EN 60529 |
Contact material |
silver |
Switching system |
slow action, positive break NC contact |
Switching elements |
change-over contact or 2 NC contacts with double break Zb, galvanically separated contact bridges |
Connection |
M3 screw clamps |
Cable section |
max. 2.5 mm2 (incl. conductor ferrules) |
Cable entries |
2 x M20 x 1.5 for cable section 5 … 9 mm |
B10d (10% Load) |
2 million |
TM |
max. 20 years |
Uimp |
4 kV |
Ui |
250 V |
Ithe |
6 A |
Ie/Ue |
6 A/250 VAC; 0.25 A/230 VDC |
Utilisation category |
AC-15, DC-13 |
Max. fuse rating |
6 A gL/gG D-fuse |
Ie/Ue solenoid |
0.08 A / 24 VDC ±10% |
Power consumption |
max. 12 W (0.25s) |
Ambient temperature |
T6: –20°C … +40ºC; T5: –20°C … +55ºC Type HU: -20°C ... +90°C |
Mechanical life |
> 1 million operations |
Holding force F |
max. 3500 N |
Holding force of integrated ball catch |
50 - 200 N, adjustable |
Ex marking |
II 2G Ex demb IIC T6/T5 Gb, II 2D Ex tb IIIC T80°C/T95°C Db IECEx Ex demb IIC T6/T5 Gb, Ex tb IIIC T80°C/T95°C Db
Type HU: II 2D Ex tD A21 IP67 T130°C, IECEx Ex tb IIIC T130°C Db IP67
|
|
Type FE-HU: II 2D Ex tD A21 IP64 T130°C, IECEx Ex tb IIIC T130°C Db IP64 |
Approvals
|
DMT 02 ATEX E 255 X, IECEx BVS 07.0018X
Type HU: BVS 08 ATEX E 155 X, IECEx BVS 12.0013X |