Ex zone 1 and 21
Double insulated
Slow action , change-over contact with double break
Cable entry M20 x 1.5
Wiring compartment
With gold-plated contacts available on request
Mounting details to DIN EN 50 047
Actuator head can be repositioned in 4 x 90° steps
Special version only for dust Ex zone 22 available
N.B.: Please state required approvals for Russia and China with your order!
Standards |
EN 60947-5-1; EN 1088; EN 60079-0, EN 60079-1, EN 60079-7; EN 61241-0, EN 61241-1; EN ISO 13849-1 |
Design |
mounting details to DIN EN 50 047 |
Enclosure |
glass-fibre reinforced, shock-proof thermoplastic, self-extinguishing UL 94-V0 |
Degree of protection |
IP 67 to IEC/EN 60529 |
Contact material |
silver |
Switching system |
slow action, positive break NC contacts |
Switching elements |
change-over contact with double break Zb or 2 NC contacts, galvanically separated contact bridges |
Connection |
M3 screw clamps |
Cable section |
max. 1.5 mm2 (incl. conductor ferrules) |
Cable entry |
M20 x 1.5 |
B10d (10% Load) |
2 million |
TM |
max. 20 years |
Uimp |
4 kV |
Ui |
250 V |
Ithe |
6 A |
Ie/Ue |
6 A/250 VAC; 0.25 A/230 VDC |
Utilisation category |
AC-15, DC-13 |
Max. fuse rating |
6 A gL/gG D-fuse |
Ambient temperature |
–20 °C … +60°C |
Mechanical life |
> 1 million operations |
Ex marking |
II 2G Ex de IIC T6, II 2D Ex tD A21 IP67 T80°C |
Approvals |
DMT 01 ATEX E 118; IECEx in 2011 |