Explosion protection |
|
|
Dust explosion protection |
II 2 D Ex tD A21 IP65 T80 °C |
Certificates |
|
|
Dust explosion protection |
PTB 06 ATEX 1019 |
Rated operational voltage Ue |
|
7060/1-1
7060/1-2
7060/1-5 |
7060/1-3
7060/1-4 |
A.C. voltage at the same potentials:
A.C. voltage at differing potentials: D.C. voltage: |
max. 500 V
max. 250 V
250 V |
max. 400 V
max. 250 V
250 V | |
Rated working current Ie |
max. 10 A |
Switching capacity |
AC 12 |
AC 15 |
DC 12 |
7060/1-1
7060/1-2
7060/1-5 |
7060/1-3
7060/1-4 |
7060/1-1
7060/1-2
7060/1-5 |
7060/1-3
7060/1-4 |
7060/1-. |
max. 250 V
max. 500 V **)
max. 10 A
max. 5000 VA |
max. 250 V
max. 400 V **)
max. 10 A
max. 4000 VA |
max. 250 V
max. 500 V **)
max. 10 A
max. 1000 VA |
max. 250 V
max. 400 V **)
max. 10 A
max. 1000 VA |
max. 125 V
max. 10 A
max. 400 W |
**) only at the same potential | |
Rated isolation voltage |
550 V |
Rated impulse withstand voltage |
6 kV |
Back-up fuse |
10 A gL / gG |
Contact block |
|
|
Version |
Slow-action contact |
|
Snap-action contact |
|
Slow-action contact, overlapping |
7060/1-1 |
|
7060/1-2 |
|
7060/1-5 |
|
7060/1-3 |
|
|
|
|
|
|
Attention: Functions positive opening and operator safety depend on actuating head used |
7060/1-4 |
|
|
|
|
| |
|
Contact arrangement |
2-pole, galvanically isolated, with double break action |
|
Clearance between open contacts |
≥ 1.5 mm (Clearance distance ≥ 3 mm) |
|
Contacts |
Silver-Nickel |
|
Life |
|
|
|
mechanical |
max. 106 Operations |
|
|
electrical |
max. 106 Operations |
|
Enclosure contact block |
- - |
Operating temperature range |
- 20 °C ... + 70 °C (6 A) |
Degree of protection |
IP 65 |
Housing |
- - |
Cable glands |
Cable entry 8161, M 20 x 1.5 |
Connection |
With cable entry 8161: For sheathed cable 4 x 5 mm2, Ø 6 - 13 mm; recommended 4 x 1.5 mm2 |
Terminals |
1 x 2.5 mm2 (solid) or 2 x 1 mm2 (flexible) |
Mechanical shock resistance |
Snap-action contact: |
2 g |
Slow-action contact: |
20 g | |