Ex zone 0 and 20
Metal enclosure
Variants for flush or non-flush mounting
Long life, no mechanical wear
Suitable for the food processing industry
Insensitive to soiling
Enclosure diameter M12 x 1
Special version only for dust Ex zone 22 available
Standards |
EN 60947-5-2; EN 50014; EN 50020; EN 50284; EN 50281-1-1 |
Enclosure |
brass-nickel, PA |
Nuts |
2, brass-nickel |
Switching system |
namur per DIN EN 60947-5-6 |
Connection |
2 m pre-wired cable PVC 2 x 0.5 mm2 |
Degree of protection |
IP 67 to IEC/EN 60529 |
Switching distance sn |
Ex IS M12 b: 2 mm, Ex IS M12 nb: 4 mm |
Switching distance in % |
steel St 37: 100 %, stainless steel: 70 %, brass: 50 %, copper: 45 %, aluminium: 40 % |
Input power Pi |
max. 50 mW |
Input voltage Ui |
max. 12.6 VDC |
Input current Ii |
max. 15.9 mA |
Tightening torque for the nuts |
M12x1: 10 Nm |
Ambient temperature |
–25 °C … +75 °C |
Ex-marking |
II 1G Ex ia IIC T6, II 1D IP67 T100°C |
Approvals |
TÜV 06 ATEX 553179 |