Ex zone 0 and 20
Metal enclosure
Variants for non-flush mounting
Long life, no mechanical wear
Suitable for the food processing industry
Insensitive to soiling
Enclosure diameter M18 x 1
Special version only for dust Ex zone 22 available
Standards |
IEC/EN 60947-5-2 |
Enclosure |
brass-nickel, PA |
Nuts |
2, brass-nickel |
Switching system |
Namur to DIN EN 60947-5-6 |
Connection |
2 m pre-wired cable PVC 2 x 0.5 mm2 |
Degree of protection |
IP 67 |
Switching distance sn |
Ex IS M12 b: 2 mm, Ex IS M12 nb: 4 mm Ex IS M18 b: 5 mm, Ex IS M12 nb: 8 mm Ex IS M30 b: 10 mm, Ex IS M30 nb: 15 mm |
Switching distance in % |
steel St 37: 100 %, stainless steel: 70 %, brass: 50 %, copper: 45 %, aluminium: 40 % |
Input power Pi |
max. 50 mW |
Input voltage Ui |
max. 12.6 VDC |
Input current Ii |
max. 15.9 mA |
Tightening torque for the nuts |
M12x1: 10 Nm, M18x1: 36 Nm, M30x1.5: 100 Nm |
Ambient temperature |
–25 °C … +75 °C |
Ex-marking |
II 1G EEx ia IIC T6, II 1D IP67 T100°C |
Approvals |
TÜV 06 ATEX 553179 |